Figure 9, 5 installation procedure – Yaskawa 1000 Series Drive Option - Open Collector Type PG User Manual
Page 20

5 Installation Procedure
20
YASKAWA ELECTRIC TOBP C730600 36C 1000-Series Option PG-B3 Installation Manual
PG Encoder Cables
Yaskawa recommends using a LMA- B-S185Y (complementary output) for cables
running between the option and the PG as show in
For instructions on wiring the terminal block, refer to
Figure 9
Figure 9 Wiring PG Encoder Cable
Table 2 Connecting the PG Encoder Cable Specification
Table 3 PG Encoder Cable Types
Option Terminal
PG Encoder Cable
Wire
Color
Pin
IP
1
Blue
C
IG
2
White
H
A+
3
Yellow
B
A–
4
White
G
B+
5
Green
A
B–
6
White
F
FE
E
N/A (shield)
D
Length
Type
Length
Type
10 m (32 ft.)
W5010
50 m (164 ft.)
W5050
30 m (98 ft.)
W5030
100 m (328 ft.)
W5100
A+ A- B+ B- Z+ Z-
SD FE
IP IG
AO IG BO IG ZO IG
L
A
B
C
D
E
F
G
H
TA1
TB1
TB2
(Pin)
3
4
5
6
E
1
2
PG encoder side
B3
This manual is related to the following products: