10 specifications – Yaskawa 1000 Series Drive Option - DeviceNet Installation User Manual
Page 35

YASKAWA ELECTRIC
TOBP C730600 43C 1000-Series Option SI-N3 Installation Manual
35
10 Specifications
10
Specifications
Table 11 Option Specifications
Items
Specifications
Model
SI-N3
SI-N3 Supported
Messages
• Group 2 Server (UCMM capable).
• Explicit Messages: Fragmentation is supported. Up to 32 bytes can be input and output.
• Polled I/O Messages: Fragmentation is not supported. Up to 8 bytes can be input and output.
• Faulted Node Recovery / Offline Connection Set Messages / Automatic Device Replacement
(ADR).
• Change of State Message (COS). COS can be used as an I/O Input Assembly.
I/O Assembly
Instance
Input: 17 types (4~8 bytes)
Output: 18 types (4~8 bytes)
DeviceNet
Specification
Conformance Level 19: Passed
DeviceNet Profile AC Drive
Input Power
Voltage: 11~25 Vdc
Current: 40 mA
Connector Type
5-pin open-style screw connector
Physical Layer
Type
Isolated Physical Layer
CAN transceiver + photocoupler
MAC ID Setting
Programmable from drive keypad or network:
MAC ID 0 to 63
Communications
Speed/Baud Rate
Programmable from drive keypad or network:
• 125/250/500 kbps
• Auto Baud Rate
• Idle Mode Detect
• Heartbeat
Ambient
Temperature
-10 °C to +50 °C (14 °F to 122 °F)
Humidity
95% RH or lower with no condensation
Storage
Temperature
-20 °C to +60 °C (-4 °F to 140 °F) allowed for short-term transport of the product
Area of Use
Indoor (free of corrosive gas, airborne particles, etc.)
Altitude
1000 m (3280 ft.) or lower