Electrical connection

Installation Guide

ST36-48US-IA-IUS112321

37

7.6.2 DC wiring of the SB 6000US/SB 7000US/SB 8000US

The Sunny Boy is configured for negative ground systems. Certain types of PV modules may require
that the positive terminal be grounded instead of the negative terminal. To configure the Sunny Boy
for positive ground, move the fuse (1) and change the jumper position (2) as shown in the following
illustrations.

Negative grounding

Following figure shows GFDI Fuse and Jumper Settings for negative grounding.

Positive grounding

Following figure shows GFDI Fuse and Jumper Settings for positive grounding.