Error Diagnosis

User Manual

SCUS-BE-BUS120514

35

65

Error text:
Overtemperature
Cause of fault:
The ambient temperature is too high.
Corrective measures:

• Check functionality of fan.
• Clean the fan.
• Clean dirty fan inlets and the ventilation plate.

70

Error text:
Temperature sensor failure
Cause of fault:

• Cable break
• Short circuit
• Internal fault of the Sunny Central.

Corrective measures:

• Check the cabling of the temperature sensor.
• Contact the SMA Serviceline.

75

Error text:
Fan failure
Cause of fault:
The ambient temperature is too high.
Corrective measures:

• Check functionality of fan.
• Clean the fan.
• Clean dirty fan inlets and the ventilation plate.

76

Error text:
Communication failure
Cause of fault:
Internal fault of the Sunny Central.
Corrective measures:

• Contact the SMA Serviceline.