SMA SC 250U User Manual
Page 35

SMA America, LLC
Error Diagnosis
User Manual
SCUS-BE-BUS120514
35
65
Error text:
Overtemperature
Cause of fault:
The ambient temperature is too high.
Corrective measures:
• Check functionality of fan.
• Clean the fan.
• Clean dirty fan inlets and the ventilation plate.
70
Error text:
Temperature sensor failure
Cause of fault:
• Cable break
• Short circuit
• Internal fault of the Sunny Central.
Corrective measures:
• Check the cabling of the temperature sensor.
• Contact the SMA Serviceline.
75
Error text:
Fan failure
Cause of fault:
The ambient temperature is too high.
Corrective measures:
• Check functionality of fan.
• Clean the fan.
• Clean dirty fan inlets and the ventilation plate.
76
Error text:
Communication failure
Cause of fault:
Internal fault of the Sunny Central.
Corrective measures:
• Contact the SMA Serviceline.
No.
Description