2 selecting where to install, Selecting where to install – SMA PT100U-NR User Manual

Page 9

background image

SMA Solar Technology AG

Installation and Electrical Connection

Installation Guide

PT100UNR-IEN083510

9

Indoors

If you protect the cable against UV radiation for use outdoors by means of a suitable cable channel,
you can also use a non-UV-resistant (indoor) cable with the basic properties mentioned above.
We recommend the following cable types:

• Lapp cable: Unitronic LiYY 4 x 0.5mm², order no.: 0028 504
• UL-listed Lapp cable: UNITRONIC LiYY UL/CSA 4 x AWG22/7, order no.: 0022 604
• Helukabel: TRONIC LiYY 4 x 0.5mm², order no.: 18087

4.2 Selecting Where to Install

• The ambient temperature sensor must be installed

with the cable gland pointing downwards in order to
prevent water from accumulating on the cable gland.

• Protect the ambient temperature sensor from severe

contamination and spray.

• See image for the recommended ambient

temperature sensor alignment.

• Select an installation site which is in shade throughout

the entire day.

• Make sure that heat cannot accumulate at the

installation site.

• Take into account the maximum cable length of 30m

(4-wire system).