beautypg.com

SMA PT100U-NR User Manual

Page 13

background image

SMA Solar Technology AG

Installation and Electrical Connection

Installation Guide

PT100UNR-IEN083510

13

4.6 Connecting the Sensor to the Sunny Boy Control Plus

The sensor is connected to the analog input port (ANALOG IN) of the Sunny Boy Control Plus.

4-wire system

The AIN-7 and AIN-8 analog input ports have been configured for a 4-wire system with
PT100 resistance. The supply currents required for this are provided by the Sunny Boy Control Plus.

2-wire system

Connecting the sensors using a connection terminal block
To connect to the Sunny Boy Control Plus, use the 25-pin connection terminal block
(see section 8 "Accessories" (page 17)).

Connecting the PT100 temperature sensor to "AIN-7" in a 4-wire system

I+ at the sensor

PIN 11 (PT100-I1+)

V+ at the sensor

PIN 9 (AIN-7+)

V- at the sensor

PIN 20 (AIN-7-)

I- at the sensor

PIN 22 (PT100-I1-)

Connecting the PT100 temperature sensor to "AIN-8" in a 4-wire system

I+ at the sensor

PIN 12 (PT100-I2+)

V+ at the sensor

PIN 10 (AIN-8+)

V- at the sensor

PIN 21 (AIN-8-)

I- at the sensor

PIN 23 (PT100-I2-)

Connecting the PT100 temperature sensor to "AIN-7" in a 2-wire system

V+ at the sensor

Bridge PIN 9 (AIN-7+) with PIN 11 (PT100-I1+)

V- at the sensor

Bridge PIN 20 (AIN-7-) and PIN 22 (PT100-I1-)

Connecting the PT100 temperature sensor to "AIN-8" in a 2-wire system

V+ at the sensor

Bridge PIN 10 (AIN-8+) with PIN 12 (PT100-I2+)

V- at the sensor

Bridge PIN 21 (AIN-8-) with PIN 23 (PT100-I2-)