Installation and Electrical Connection

SMA Solar Technology AG

12

PT100UNR-IEN083510

Installation Guide

3. Unscrew the cable gland sleeve nuts on the bottom

center of the Sunny SensorBox and remove the filler
plugs.

4. Thread the sensor cable through the sleeve nuts

and tighten the cable gland of the Sunny
SensorBox.

5. Remove the resistor and the bridge at the

"F6 TmpAmb" connection in the Sunny SensorBox.

6. Connect the sensor to the "F6 TmpAmb" connection

in the Sunny SensorBox. Note the indicated wire
colors (see page 10).

7. Ensure that the cable gland grommet is correctly in

place.

8. Screw the sleeve nuts tightly onto the cable gland

to fix the cable (torque: 0.8Nm).

9. Lay the cable using suitable fastening material.

10. Install and connect further sensors.
11. Place the Sunny SensorBox enclosure lid on the

lower enclosure shell.

12. Initially turn the screws of the enclosure lid a little to

the left, until the screws fall into the first turn of the
thread.

13. Turn the screws tightly (torque: 1 Nm) into the lower enclosure shell.

☑ The ambient temperature sensor is now connected.

Sensor Configuration
Refer to the Sunny SensorBox installation guide for the sensor configuration.