SMA SSM8-21-BS User Manual
Page 33

SMA Solar Technology AG
6 Electrical Connection
Installation Manual
SSMxx-21-IA-BS-JP-en-20
33
• Let go of the actuation lever.
• Ensure that the insulated conductors are firmly in place.
4. Bundle the insulated conductors of the data cables with a cable tie.
5. Position the bootlace ferrule between the data cables and the
connector.
6. Attach the data cables to the connector using two cable ties.
Pin 3
RS485H
yellow
Pin 4
+60V_EXT
Conductor pair: gray/pink
Pin 5
GND_EXT
Conductor pair: white/brown
Pin 6
RS485L
green
Pin 7
RS485H
yellow
Pin 8
+60V_EXT
Conductor pair: gray/pink
* as per DIN EN 47100; the color of the insulated conductor can vary depending on the cable
Terminal
Signal
Color of insulated conductor*
This manual is related to the following products: