Event number
Message, cause and corrective measures
7329
Condition test successful
The testing of the update conditions was successful. The firmware update
package is suitable for this inverter.
7330
Condition test failed
The testing of the update conditions was not successful. The firmware update
package is not suitable for this inverter.
Corrective measures:
• Retry update.
• Ensure that the selected update file is suitable for this inverter.
• If this message is displayed again, contact the Service (see Section 11
7331
Update transport started
Update file is being copied.
7332
Update transport successful
Update file was copied successfully to the inverter's internal memory.
7333
Update transport failed
Update file could not be copied to the inverter's internal memory. In the event
of connection with the inverter via WLAN, a poor connection quality can be
the cause.
Corrective measures:
• Retry update.
• For WLAN connection: Improve the WLAN connection quality (e.g. via
WLAN repeater) or establish connection with the inverter via Ethernet.
• If this message is displayed again, contact the Service (see Section 11
7341
Update Bootloader
The inverter is performing a bootloader update.
7342
Update Bootloader failed
The bootloader update failed.
Corrective measures:
• Retry update.
• If this message is displayed again, contact the Service (see Section 11