Mod functions 16.9 ethernet interface – HEIDENHAIN TNC 620 (34056x-04) User Manual
Page 510

MOD functions
16.9 Ethernet interface
16
510
TNC 620 | User's Manual
HEIDENHAIN Conversational Programming | 5/2013
Settings on a PC with Windows 2000
Prerequisite:
The network card must already be installed on the
PC and ready for operation.
If the PC that you want to connect the TNC to is
already integrated in your company network, then
keep the PC’s network address and adapt the TNC’s
network address accordingly.
To open Network Connections, click Start, Settings, and then
Network and Dial-up Connections.
Right-click the LAN connection symbol, and then Properties in
the menu that appears
Double-click Internet Protocol (TCP/IP) to change the IP settings
(see figure at top right)
If it is not yet active, select the Use the following IP address
option
In the input field, enter the same IP address that you entered for
the PC network settings on the iTNC, e.g. 160.1.180.1
Enter 255.255.0.0 in the Subnet mask input field
Confirm your entries with OK
Save the network configuration with OK. You may have to