Appliance function

The fully electronically controlled ELECTROLUX IH instant water heater is a

pressurised appliance for the supply of one or more tapping points and heats

the water as the latter continuously flows through it. A flowrate sensor switches

on the heating at a flowrate of around 3 l/min and off again at around 2,5 l/min.

The microprocessor controlled electronic system automatically adapts the

heating power with regard for the inlet temperature, the temperature set on the

temperature selector knob, and the water flowrate. The user thus has hot

water available in an energy-saving system giving the exact temperature required

without any time limitation whatever.

The nominal operating pressure is 1 Mpa. If this value is exceeded, a pressure

reducing valve should be provided in the household pipework. A safety valve is

not necessary.

The bare wire resistance heating system has a high efficiency. Its low weight

and extremely low water content also make it suitable for hard, lime-containing

water qualities.

Safety temperature and pressure limiter

In the event of a fault, the inbuilt safety

temperature limiter isolates the appliance from

the mains supply on all contacts.

Before the appliance is switched back on, a

trained engineer must ascertain and eliminate

the cause of the fault (see page 17). Then

carefully press in the contact rocker with a

screwdriver until it audibly engages.

Important! The safety temperature and pressure limiter should never

be adapted or modified in any way!

Important: Don't block up the contact rocker!