Hot water flowrate

Up to the appliance’s max. power limit, the instantaneous water heater

supplies the set hot water temperature regardless of the water flowrate

selected.

If the hot water temperature is not attained when the hot water valve

is fully opened, more water flows than can be heated by the

appliance power. In this case, the hot water tap must be slightly

closed.

Because of the different inlet temperatures, the hot water output varies

depending on the season.

The following outlet flowrates for bath or shower water (40°C) or washbasin/

sink water (55°C) are attained at the inlet temperatures of 6°C, 10°C,

and 14°C.

Care and maintenance of the appliance

Clean the plastic housing as necessary with a damp cloth and dilute soap

solution. Never use any abrasive, scouring, and solvent-containing detergents.

The instantaneous water heater generally needs no maintenance. Regular

inspection of the appliance by a trained engineer will ensure its operational

reliability and prolong its service life.

Scale deposits in the outlet of fittings reduce the water flowrate. The air

bubblers of the fittings or hand shower head must therefore be cleaned from

time to time.

Cold

water

tempe

rature

°C

Outlet temperature

40°C

Outlet temperature

55°C

6

10

14

18 kW

l/min

7,6

8,6

(*8)

9,9

(*8)

21 kW

l/min

8,8

10

(*9)

11,6

(*9)

24 kW

l/min

10,1

11,5

(*10)

13,2

(*10)

18 kW

l/min

5,3

5,7

6,3

21 kW

l/min

6,1

6,7

7,3

24 kW

l/min

7

7,6

8,4

(*) limited to this figure by the built-in flow limiter