5

Important instructions for the installer

General

The instantaneous water heater is manufactured and tested in conformity with

the valid IEC specifications and DIN standards. The appliance complies with

the Appliance Safety Act. The indications given on the rating plate, the technical

connection specifications of the electricity and water companies in the

geographical area concerned, and VDE 0100 and DIN 1988 must be observed

when the appliance is being installed.

The specific resistance of the water at the installation site should not

be less than 1100

cm.

This appliance complies with the following EC Directives:

Appliance constitution

- the ”Low-Voltage Directive” 72/23/EEC of 19.02.1973, including

Amendment Directive 93/68/EEC

- the”Electromagnetic Compatibility” Directive 89/336/EEC of

03.05.1989 including Amendment Directive 92/31/EEC

1 =Back wall

2 =Quick fastener for appliance

mounting

3 =Upper cable bushing

3a = Lower cable bushing

4 =Upper mains connection

terminal (factory-prefitted)

5 =Flowrate sensor

6 =Safety temperature and

pressure limiter

7 =Electronic module

8 =Temperature selector knob

9 =Flowrate limiter

10 =Strainer insert

11 = Cold water connection

12 =Hot water connection

13 =Thermostat

14 =Heating block

1

2

3

4

5

10

11

3a

4a

12

6

7

8

9

13

14

This manual is related to the following products: