Check the voltage

Clean strainer insert (see

page 12)

Dismantle and clean the

bubblers and showers

heads

Inspection and repair only

by the trained engineer

Inspection and repair only

by the trained engineer

Inspection and repair only

by the trained engineer

Cause

Fault

Remedy

- Appliance is not live

- Strainer insert is

clogged

- Soiling or scaling of

bubblers and shower

heads

- Defective heating

system

- Inadmissibly high cold

water inlet tempera-

ture (over 25 °C)

- Inadmissibly high

outlet temperature

(over 70 °C)

- System fault (see

table on page 18)

- Heating system does

not switch on

- Hot water flowrate too

low

- Safety temperature and

pressure limiter has

tripped

- Active fault indicator

(LED)

Appliance should not be

operated with preheated

water.

Fault-finding (important instructions for the trained engineer)

In the event of any fault, a check should first be made to ascertain

whether the fuse and line protection switch have tripped.