18

Fault indications

- L1 or L3 phase missing

- L2 phase missing

*) The individual fault are indicated every 5 sec. The indication mode starts

afresh every 40 sec.

Important! If the fault has been rectified, the fault memory goes automati-

cally in Reset - Function.(Sometimes with cold water flow phase ca.15 sec.)

Fault

pattern

Idicator

Possible faults

LED 1

LED 2

1

No display

Appliance does

not work

- Flowrate sensor not plugged

/ defective

Setpoint temperature

not reachd

2

FLASHES

long

FLASHES

long

- Setpoint generator not fitted

3

No display

warm water temp. 37°C

Constant

FLASHES

long

FLASHES

short

No heat output

- Electronics defective

FLASHES

long

ON

No heat output

4

- Supply temperature over 25°C

5

ON

No heat output

- Water flow over 20l/min