Specifications – Grass Valley Triton Plus Revision 3 User Manual
Page 23

Triton Plus - Control Panels - User Manual
23
Specifications
Specifications
Note
All specifications are subject to change without notice.
Table 15. Triton Plus Control Panel Specifications
Parameter
Value
Mechanical
Dimensions
• HxWxD = 44x483x50mm (19 in., 1 RU)
• HxWxD = 88x483x50mm (19 in., 2 RU)
• HxWxD = 176x483x50mm (19 in., 4 RU)
Safety/Emission standards
Compliant with CE EN55103-1 and 2
Power Supply
TPS-PWR-40
40W power supply unit for 8x8 to 32x32
AC supply voltage range
100-240VAC, 50-60Hz max 1.6A
AC mains connector
IEC 320
DC output
• +15V, max. 2.2A/-15V, max 1.35A.
• Maximum 43W for 8x8–32x32 versions
DC connector
DB9, female
Status monitoring
Via LED in front of router/CP
Control
Standard Features
Serial port
RS-232 for protocol conversion, to Triton Plus compact control protocol, or
to 3rd party protocols
Connector
DB9, female
NCB ports
For integration with Triton Plus compact router configuration
Connectors (2)
RJ45 (1 in/1 out)
Ethernet port
10/100BaseT Ethernet is not supported at this time
Connector
RJ45
Environmental
Equipment will meet guaranteed performance specifications under the following conditions:
Operating room temperature range
0º C to 45º C
Operating relative humidity range
< 95% (non-condensing)
Equipment will operate without damage under the following conditions:
Temperature range
-10º C to 55º C
Relative humidity range
< 95% (non-condensing)