Gpi connections – Grass Valley Triton Plus Revision 3 User Manual
Page 20

20
Triton Plus - Control Panels - User Manual
GPI Connections
GPI Connections
Note
This information is applicable only on GPI panel versions.
The GPI / Joystick / Tally signals are connected to the Triton Plus Control
Panel with GPI options using DB25 male connectors. Each Triton Plus CP
with GPI I/O has 32 GPI inputs and 32 GPI outputs available, independent
of panel size.
Note
The GPI connectors on the CP are DB25 females.
The GPI pinouts are given in
All inputs internally connected to +5V via a pull-up resistor. The inputs will
be activated when pulling them to ground. Ground is available on the fol-
lowing pins: 2, 5, 8, 11, 13, 16, 19, 22, 25 and on the connector chassis.
All outputs are of open collector type. An output can switch a maximum
load of 100mA at 30V. Any device to be controlled by the GPI outputs
(lamp, LED or similar) needs to be connected to an external supply voltage
on one end and to the GPI output on the other end.
WARNING
Do not connect external supply voltages higher than 30V DC.
Table 13. GPI Pinouts
GPI I/O Channel #
Connector Pin #
1 and 17
12
2 and 18
24
3 and 19
23
4 and 20
10
5 and 21
09
6 and 22
21
7 and 23
20
8 and 24
07
9 and 25
06
10 and 26
18
11 and 27
17
12 and 28
04
13 and 29
03
14 and 30
15
15 and 31
14
16 and 32
01