beautypg.com

Termination plug – Grass Valley Triton Plus Revision 3 User Manual

Page 18

background image

18

Triton Plus - Control Panels - User Manual

Router Communication

The following connection example (

Figure 2

) shows connection of four

Triton Plus devices with RJ45 connectors and bus termination:

Figure 2. Four Devices Connected Together Using RJ45

Note

Each device at the end of the chain has a termination plug, indicated with the
letter T. This termination plug must be inserted in the correct connection port.
If not, no NCB communication is possible.

Termination Plug

The termination plug that is mentioned in the previous chapter is necessary
when you want to avoid closing the loop with a (long) cable.

The termination plug is a standard RJ45 plug with the following internal
wiring shown in

Figure 3

.

Figure 3. RJ45 Termination Plug Wiring

Pin 3 is connected to Pin 4

Pin 5 is connected to Pin 6