Bypass relay module, Breakout cable, Indicator leds – Grass Valley Kalypso Emergency Bypass Option User Manual
Page 27: Relay module switch

Kalypso Emergency Bypass Option Instruction Manual
27
Maintenance
Bypass Relay Module
Indicator LEDs
The Emergency Bypass Relay module (
Figure 12
) has a single Power LED,
and two operating mode LEDs above and below the mode switch. The top
red LED indicates the module is in bypass operation. The lower green LED
indicates normal (non-bypass) operation.
Figure 12. Bypass Relay Module
Relay Module Switch
The three position switch (SW 1) can be used to change module operating
modes. The up position forces bypass operation, and the bottom position
forces normal (non-bypass) operation. The center
Remote
position permits
remote mode switching from the Local Aux panel.
Breakout Cable
The breakout Y cable (
Figure 13
) used between the Local Aux panel and
Emergency Bypass frame includes a BNC connector, which is used for
contact closure.
Figure 13. Breakout Cable and Pin Connections
SW1 – three position switch
(center position REMOTE)
PWR
BYPASS
NORMAL
8121_01_02
J1
DB-9
Female
P1
DB-9
Male
P2
BNC
8121_01_03_r1
From
To
Note
J1-1
P1-5
Use cable drain wire
J1-2
P1-2
Twisted pair
J1-7
P1-7
J1-4
P2-Center
BNC connector
J1-6
P2-Shield
J1-3
P1-3
Twisted pair
J1-8
P1-8