Maintenance
Enabling Alarms and Fan Speed Control Option
The Bypass Frame Monitor Module has an eight position DIP switch (S1)
that enables or disables the alarm functions and the variable fan speed
function, same as a standard 8900 Frame Monitor module. In addition, an
RS-422 setting used only by the Bypass module is available, but must be set
to the normal position.
Refer to
Figure 10
for the location of S1 and
Table 2
for the possible settings.
FAN
(red)
Off
Normal operation or alarm disabled
On continuously
One or more fans in the front cover assembly is not rotating
MOD
(red)
Off
Normal operation or alarm disabled
On continuously
Module health bus is not disabled and one or more modules is reporting an internal fault
Flashing
One or more modules is reporting a data error
INHIB
(yellow)
Off
Normal operation or alarm disabled
On continuously
A non-compliant module in the frame has disabled the module health bus
FAULT
(red)
Off Normal
operation
On continuously
One or more of the onboard fault LEDs is illuminated or flashing
Table 2. Configuration DIP Switch Settings
Segment
Left Position (open)
Right Position (closed)
1
PS1 Fault Reporting Enabled
PS1 Fault Reporting Disabled
2
PS2 Fault Reporting Enabled
PS2 Fault Reporting Disabled
3
Overtemp Fault Reporting Enabled
Overtemp Fault Reporting Disabled
4
Fan Fault Reporting Enabled
Fan Fault Reporting Disabled
5
Module Fault Reporting Enabled
Module Fault Reporting Disabled
6
Fan Speed Controlled by Temperature
Fan Speed Fixed at Maximum
7
Not Used
8
RS-422 Normal
RS-422 Reversed
a
a
Emergency Bypass does not operate with a reversed setting.