Maintenance
Bypass Keyer Module
Indicator LEDs
The Bypass Keyer module has LED indicators above the rotary switch
(
Figure 11
).
Figure 11. Bypass Keyer Module
The possible LED status and conditions indicated are shown in
Table 1
.
Table 1. Indicator LEDs and Conditions Indicated
LED
LED State
Condition
FAULT
(red)
Off Normal
operation
On continuously
Module FPGA is not configured or fails to configure
COMM
(yellow)
Off
-
Flickers
Communications activity under way
CONF
(yellow)
Off
-
On continuously
Module is being configured
PWR
(green)
Off
Power is off or onboard regulator has failed
On continuously
Module is powered
625
(green)
Off
-
On continuously
625 line reference is detected
LOCK
(red)
Off
-
On continuously
Module has acquired lock on reference input
REF
PRESENT
(red)
Off
Reference signal not detected
On continuously
Reference signal detected
FUNCTION – rotary switch
(1-Shaped, 2-Unshaped)
SW1 – actuator toggle switch
JP3 – jumper required on right
CONF
PWR
COMM
FAULT
REF PRESENT
LOCK
625
JP4
JP3
JP2
JP1