K2 raid for basic k2 san – Grass Valley K2 Storage User Manual
Page 55

01 April 2010
K2 Storage Cabling Guide
55
K2 RAID for basic K2 SAN
K2 RAID for basic K2 SAN
These cabling instructions apply to the following:
• Level 3 (NEC 1400) K2 RAID on a Level 3 basic (non-redundant) K2 SAN.
Primary Chassis
Expansion Chassis 1
Expansion Chassis 2
Set address to 0
Set address to 1
Set address to 0
Set address to 1
DL1
DL0
To K2 Media
Server 2
To Expansion
Chassis 3,
with address
set to 1
To Expansion
Chassis 4,
with address
set to 2
To K2 Media
Server 1
To control port
on GigE switch
The cable/address pattern, extended for
additional Expansion Chassis, is as follows:
Expansion Connect Set
address
Chassis #
to...
to...
1
DL1
0
2
DL0
1
3
DL1
1
4
DL0
2
5
DL1
2
6
DL0
3
7
DL1
3
For more information, refer to the K2
Storage System Instruction Manual.