Dell 2950 for basic k2 san, Dell 2950 for redundant k2 san, Chapter 2 cable k2 devices – Grass Valley K2 Storage User Manual
Page 38

38
K2 Storage Cabling Guide
01 April 2010
Chapter 2 Cable K2 devices
Dell 2950 for basic K2 SAN
These cabling instructions apply to the following:
• Dell 2950 PowerEdge Server with two iSCSI interface adapters (TOEs) on a basic
(non-redundant) online K2 SAN.
Dell 2950 for redundant K2 SAN
These cabling instructions apply to the following:
• Dell 2950 PowerEdge Server with two iSCSI interface adapters (TOEs) on a
redundant online K2 SAN.
PCI 1
PCI 2
PCI 3
Gb 1
Gb 2
Fibre Channel
to RAID controller
To control port
on GigE switch
FTP: To control port
on GigE switch
To media (iSCSI)
ports on GigE switch
PCI 1
PCI 2
PCI 3
Gb 1
Gb 2
Fibre Channel
to RAID controller
PCI 1
PCI 2
PCI 3
Gb 1
Gb 2
A
To control port
on GigE switch A
FTP: To control port
on GigE switch A
To control port
on GigE switch B
FTP: To control port
on GigE switch B
B
Heartbeat
cable
(serial)
To media (iSCSI)
ports on GigE switch A
To media (iSCSI)
ports on GigE switch B
Fibre Channel
to RAID controller