beautypg.com

Dell 2950 for basic k2 san, Dell 2950 for redundant k2 san, Chapter 2 cable k2 devices – Grass Valley K2 Storage User Manual

Page 38

background image

38

K2 Storage Cabling Guide

01 April 2010

Chapter 2 Cable K2 devices

Dell 2950 for basic K2 SAN

These cabling instructions apply to the following:

• Dell 2950 PowerEdge Server with two iSCSI interface adapters (TOEs) on a basic

(non-redundant) online K2 SAN.

Dell 2950 for redundant K2 SAN

These cabling instructions apply to the following:

• Dell 2950 PowerEdge Server with two iSCSI interface adapters (TOEs) on a

redundant online K2 SAN.

PCI 1

PCI 2

PCI 3

Gb 1

Gb 2

Fibre Channel
to RAID controller

To control port
on GigE switch

FTP: To control port
on GigE switch

To media (iSCSI)
ports on GigE switch

PCI 1

PCI 2

PCI 3

Gb 1

Gb 2

Fibre Channel
to RAID controller

PCI 1

PCI 2

PCI 3

Gb 1

Gb 2

A

To control port
on GigE switch A

FTP: To control port
on GigE switch A

To control port
on GigE switch B

FTP: To control port
on GigE switch B

B

Heartbeat
cable
(serial)

To media (iSCSI)
ports on GigE switch A

To media (iSCSI)
ports on GigE switch B

Fibre Channel
to RAID controller

This manual is related to the following products: