Grass Valley FIO-1901-TT User Manual
Page 19

GUIDE TO INSTALLATION AND OPERATION
FIO-1901-TT | 15
3.3.7 The
Alarm Config panel
This panel allows the alarm
reporting of the FIO-1901-TT
to be configured.
Click on the Alarm Config
button to open the Alarm
Configuration window.
The Alarm Configuration
window is organized in
columns
Status/Name
This contains an expandable tree listing all the alarms reported by this FIO-1901-TT card.
• Each alarm name includes an icon that shows its current status
The Card LED, Overall alarm and GSM contribution columns contain pulldown lists that allow the level of
contribution of each individual alarm to the alarm named in the column heading to be set.
¾ Click on the alarm icon to see the available levels; then click on one to select it
Card LED
This column allows configuration of the contribution of each individual alarm to the status reported by the Status
LED on the front edge of the FIO-1901-TT card, visible through the front door of the Densité frame.
Overall Alarm
This column allows configuration of the contribution of each individual alarm to the Overall Alarm associated with
this card. The Overall Alarm is shown in the upper left corner of the iControl panel, and also appears at the bottom
of the Status/Name column.
GSM Contribution
This column allows configuration of the contribution of each individual alarm to the GSM Alarm Status associated
with this card. GSM is a dynamic register of all iControl system alarms, and is also an alarm provider for external
applications. The possible values for this contribution are related to the Overall alarm contribution:
Figure 3.9 Alarm Configuration panel