beautypg.com

1 overview – Grass Valley DEC-1023 User Manual

Page 10

background image

GUIDE TO INSTALLATION AND OPERATION

6 | DEC-1023

LED Status


Error Condition

Green Yellow Red

Flashing

Red

No rear panel

›

Hardware error

›

No SDI signal

›

No audio grp 1

›

No audio grp 2

›

No audio grp 3

›

No audio grp 4

›

Silence Ch. 1

›

Silence Ch. 2

›

Silence Ch. 3

›

Silence Ch. 4

›

Silence Ch. 5

›

Silence Ch. 6

›

Silence Ch. 7

›

Silence Ch. 7

›

Overload

›

Test

›

Card system

›

› : Factory default.


If the LED is Flashing Yellow, it means that the card is selected for local control using the Densité frame’s
control panel. See Section 3.3 for details.

3.3 Local control using the Densité frame control panel

3.3.1 Overview


Push the SELECT button on the DEC-1023 card edge (see Section 1.5) to assign the local control panel to
operate the DEC-1023. Use the control panel buttons to navigate through the menu, as described below.

All of the cards installed in a Densité frame are connected to the frame’s controller card, which handles all
interaction between the cards and the outside world. There are no operating controls located on the cards
themselves. The controller supports remote operation via its Ethernet ports, and local operation using its
integrated control panel.

The local control panel is fastened to the controller
card by a hinged connector, and when installed is
located in the front center of the frame, positioned in
front of the power supplies. The panel consists of a
display unit capable of displaying two lines of text,
each 16 characters in length, and five pushbuttons.

The panel is assigned to operate any card in the
frame by pushing the SELECT button on the front
edge of that card.











Figure 3.1 Densité Frame local control panel

• Pushing the CONTROLLER button on the control panel selects the Controller card itself.

SELECT

ESC

+

-

CONTROLLER

This manual is related to the following products: