Functions – Grass Valley 2030RDA User Manual
Page 24

24
2030RDA Instruction Manual
Configuration and Monitoring
Slot Config Web Page
Use the Slot Config web page (
) to perform the fol-
lowing functions on the 2030RDA module:
•
Locate Module
– selecting the
Flash
radio button lights the yellow COMM
and red FAULT LEDs for 3 quick flashes on the front of the module so
it can be located in the frame.
•
Slot Identification
– You may identify the module by typing a specific
name in the
Name
field. The assigned name is stored on the 2000NET
module and travels with the 2000NET module if it is moved to another
frame. Select
Default
to enter the factory default module name.
You may also assign a name to the input signal in the
Input Signal Name
field. Select
Default
to enter the factory default signal name.
An asset identification may be entered in the
Asset Tag
field. This will
appear on the module Status web page and in the NetConfig inventory
report.
•
Slot Memory
– the slot configuration for each media module is automati-
cally saved periodically (once an hour) to the 2000NET module in that
frame. You may also select the
Learn Module Config
button at any time to
save the current configuration for this slot. The configuration is saved
on the 2000NET module. If the 2000NET module is removed or
powered down, the stored configurations are not saved.
When the
Restore upon Install
box has been checked, the current configu-
ration saved to this slot is saved as slot memory. When the current
module is removed and another module of the same type is installed,
the configuration saved to the 2000NET module will be downloaded to
the new module. The box must be checked before the current module
with the saved configuration is removed.
•
Frame Heath Reporting
– the reporting of Slot Fault, Signal Loss, and Ref-
erence Loss can be enabled or disabled to the Frame Health connector
on the rear of the Kameleon 2000T3 frame by selecting or deselecting
the corresponding checkbox.
•
Hardware Switch Controls
– a read-only status report of 2000NET module
switch settings for Module Status Reporting and Asynchronous Status
Reporting (dipswitch S1 segment 7 and dipswitch S2 segment 1). These
functions must be enabled for the following Slot SNMP Trap Reports to
function.