Configuration and monitoring, Configuration summary – Grass Valley 2030RDA User Manual
Page 14
14
2030RDA Instruction Manual
Configuration and Monitoring
Configuration and Monitoring
The 2030RDA can be configured locally using on-board switches or
remotely using the 2000NET network interface GUI or a Newton Control
Panel. Operation of these control types is explained in detail in their respec-
tive sections of this manual.
Note
Not all available functions are configurable with the local on-board controls.
Refer to the following sections for configuration instructions:
•
Configuration Summary (
)
•
Local On-board Configuration (
)
•
Remote Configuration and Monitoring (
)
Configuration Summary
The configuration parameters and monitoring functions available with the
local on-board jumpers, web browser interface, and the Newton Control
Panel are summarized in
. The parameter defaults, choices, ranges,
and resolution are provided for each function.
Table 3. Summary of 2030RDA Configuration Functions
Function
Type
Default
Range/Choices
Resolution
Web Page/
Function Name
On-Board
Jumper Setting
Newton
Control
Panel
Mode
Auto
Auto
Manual
Bypass
Standard Selections/
Mode Pulldown
JP25 pins 1-2 = AUTO
JP25 pins 2-3 = BYPASS
Mode
Manual standard
selection
–
Manual 143Mb
Manual 177Mb
Manual 270Mb
Manual 360Mb
Standard Selections/
Mode Pulldown/
Manual mode
No on-board manual
selections available.
StdSel
Recall factory
defaults
–
See Default column
Recall Factory Defaults
Recall Fact.
Default
button
N/A
N/A