Grass Valley 2030RDA User Manual
Page 21

2030RDA Instruction Manual
21
Configuration and Monitoring
Standard Selection Web Page
The Standard Selection web page (
) provides both status reporting and controls for the module.
The following parameter controls are provided on the Settings web page.
Select the
Apply
button after each parameter selection.
Mode
Set the reclocking mode to one of the following with the menu pulldown:
•
Auto
– if the module detects the input signal as one of the SMPTE stan-
dard definition rates (143 Mb/s, 177 Mb/s, 270 Mb/s, 360 Mb/s, or
540 Mb/s), it will reclock the signal at that rate. If one of these rates is
not detected, the module will not reclock the signal (bypass the
reclocker) and distribute the signal to the outputs.
•
Manual
– set the mode to lock to one of the following data rates:
•
143Mb
– the module will attempt to reclock the input signal at 143
Mb/s. If this signal rate is not detected, the signal will not be
reclocked and will be passed to the output as is (corrupted).
•
177Mb
– the module will attempt to reclock the input signal at 177
Mb/s. If this signal rate is not detected, the signal will not be
reclocked and will be passed to the output as is (corrupted).
•
270Mb
– the module will attempt to reclock the input signal at 270
Mb/s. If this signal rate is not detected, the signal will not be
reclocked and will be passed to the output as is (corrupted). This
setting is recommended for DVB-ASI signals.
•
360Mb
– the module will attempt to reclock the input signal at 360
Mb/s. If this signal rate is not detected, the signal will not be
reclocked and will be passed to the output as is (corrupted).
•
Bypass
– reclocking is completely bypassed. The input signal passes
directly to the outputs without reclocking.
Note
For DVB-ASI signals, set the mode to Manual – 270 Mb.