Slot configuration, Locate module, Slot identification – Grass Valley 2000GEN User Manual
Page 14

14
2000GEN Instruction Manual
Remote Control and Monitoring
Slot Configuration
The Slot Config display (
) allows you to do the following:
•
Activate/deactivate the module locator function,
•
Type a specific name for the module and the input signal, and
•
Report and enable/disable SNMP reporting for the slot.
Locate Module
When enabled, the
Locate Module
function blinks the yellow COMM and
CONF LEDs three times on, then a long off period, to make the module
easy to locate in the frame.
Slot Identification
In the
Slot Identification
Name and Input Signal Name fields, you can type an
identifying name for the module and a name to identify the input signal.
The assigned names are stored on the 2000GEN module and travel with the
module if it is moved to another frame.
Figure 9. 2000GEN Slot Config Screen
Use
This
Link
Read-only status of 2000NET
module hardware settings
necessary for enabling
SNMP Trap Reports
Enable/disable specific
SNMP reports for the slot
Read-only severity level
assigned to each event
Name the module slot
Name the input signal
Learn module configuration
to this slot
Check box to restore saved config
when new module installed
Enable/disable module
locator function