Configuring the inform interval, Configuring the polling interval, Configuring access parameters – H3C Technologies H3C Intelligent Management Center User Manual
Page 28: Configuring the file transfer type

19
Configuring the inform interval
This function enables you to set the interval at which the system polls the specified CPEs. The system reads
the configuration of the specified CPEs at the interval, and updates the system database.
To configure the inform interval in batches:
1.
Click Service > BIMS > Resource Management > Batch Operate.
2.
On the Batch Operate page, click Configure Inform Interval.
3.
On the Periodic Inform Interval page, click Add CPE.
4.
On the CPE List page, select the target CPEs, and then click OK.
5.
Specify an Inform interval for all target CPEs, and then click Apply.
With periodic inform enabled, the inform interval (an integer in seconds) is the interval at which
the CPE tries to connect to the ACS and invokes the inform method.
Configuring the polling interval
To configure the polling interval in batches:
1.
Click Service > BIMS > Resource Management > Batch Operate.
2.
On the Batch Operate page, click Configure Polling Interval.
3.
On the Configure Polling Interval page, click Add CPE.
4.
On the CPE List page, select the target CPEs, and then click OK.
5.
Specify a Status Polling Interval and Configuration Polling Interval for all target CPEs, and then
click Apply.
With periodic inform enabled, the inform interval (an integer in seconds) is the interval at which
the CPE tries to connect to the ACS and invokes the inform method.
Configuring access parameters
To configure the access parameters in batches:
1.
Click Service > BIMS > Resource Management > Batch Operate.
2.
On the Batch Operate page, click Configure Access Parameters.
3.
On the Configure Access Parameters page, click Add CPE.
4.
On the CPE List page, select the target CPEs, and then click OK.
5.
Specify the Connection Request Username and Connection Request Password for all target CPEs,
and then click Apply.
The Connection Request Username and Connection Request Password are used to initiate a
connection request to the CPE from the ACS. The password read from CPEs is a null string rather
than the actual value.
Configuring the file transfer type
This function helps you modify the protocol to HTTP or HTTPS. It is used for transferring files between the
specified CPE and the BIMS server. The default protocol is HTTP.