Enabling the ACFP trap function on the device

To make ACFP work, enable the device to send trap messages of the ACFP module.
After the trap function on the ACFP module is enabled, the ACFP module generates trap messages to
report important events. The levels of the ACFP trap messages are described in

Table 1

.

Table 1 ACFP trap message level

Trap message Level

Context ID type changed

Notifications

ACFP client registration

Notifications

ACFP client deregistration

Notifications

ACSEI detects that ACFP client had no response

Warnings

ACFP server does not support the working mode of the ACFP client

Errors

Expiration period of ACFP collaboration policy changed

Notifications

ACFP collaboration rules are created

Informational

ACFP collaboration rules are removed

Informational

ACFP collaboration rules failed

Errors

Expiration period of ACFP collaboration policy timed out

Notifications

The generated trap messages are sent to the information center of the device. With the parameters for the

information center set, the output rules for traps (that is, whether the traps are allowed to be output and

the output destinations) are decided. For more information about the configuration of the parameters for
the information center, see Network Management and Monitoring Configuration Guide.
To enable the ACFP function:

Step Command

Remarks

3.

Enter system view.

system-view

N/A

4.

Enable the trap function of the
ACFP module.

snmp-agent trap enable acfp
[ client | policy | rule | server ]

Optional.
Enabled by default.

For more information about the snmp-agent trap enable command, see Network Management and

Monitoring Command Reference.