Displaying and maintaining bfd – H3C Technologies H3C MSR 5600 User Manual
Page 61
53
Step Command
Remarks
5.
Configure the multi-hop
detection time multiplier.
bfd multi-hop detect-multiplier
value
The default setting is 5.
6.
Configure the minimum
interval for receiving multi-hop
BFD control packets.
bfd multi-hop min-receive-interval
value
The default setting is 1000
milliseconds.
7.
Configure the minimum
interval for transmitting
multi-hop BFD control packets.
bfd multi-hop
min-transmit-interval value
The default setting is 1000
milliseconds.
Displaying and maintaining BFD
Execute the display command in any view and the reset command in user view.
Task Command
Display BFD session information.
display bfd session [ discriminator value | verbose ]
Clear BFD session statistics.
reset bfd session statistics