beautypg.com

Installation requirements, Important, Electrical system requirements – Electrolux 134709300 User Manual

Page 4

background image

4

Installation Requirements

IMPORTANT

This dryer is internally grounded to neutral unless it
was manufactured for sale in Canada. Grounding
through the neutral link is prohibited for: (1) new
branch circuit installations, (2) mobile homes, (3)
recreational vehicles, and (4) areas where local
codes do not permit grounding through the neutral.

NOTE

Dryers manufactured for sale in Canada have
factory-installed, 4-wire power supply cord
(NEMA 14-30R).

Electrical system requirements

Electrical requirements for electric dryer:

CIRCUIT - Individual 30 amp. branch circuit

fused with 30 amp. time delay fuses or circuit
breakers. Use separately fused circuits for
washer and dryer. DO NOT operate a washer
and a dryer on the same circuit.

POWER SUPPLY - 3-wire or 4-wire, 240 volt,

single phase, 60 Hz, Alternating Current.

3-WIRE POWER SUPPLY CORD KIT (not supplied)

OUTLET RECEPTACLE - NEMA 10-30R or NEMA

14-30R receptacle to be located so the power
supply cord is accessible when the dryer is in the
installed position.

GROUNDING CONNECTION - See “Grounding

requirements” in Electrical Installation section.

The dryer MUST employ a 3-conductor power
supply cord NEMA 10-30 type SRDT rated at
240 volt AC minimum, 30 amp, with 3 open
end spade lug connectors with upturned ends
or closed loop connectors and marked for use

4-WIRE POWER SUPPLY CORD KIT (not supplied)

The dryer MUST employ a 4-conductor power
supply cord NEMA 14-30 type SRDT or ST (as
required) rated at 240 volt AC minimum, 30 amp,
with 4 open end spade lug connectors with
upturned ends or closed loop connectors and
marked for use with clothes dryers. For 4-wire
cord connection instructions see ELECTRICAL
CONNECTIONS FOR A 4-WIRE SYSTEM.

Electrical requirements for gas dryer:

CIRCUIT - Individual, properly polarized and

grounded 15 amp. branch circuit fused with 15
amp. time delay fuse or circuit breaker.

POWER SUPPLY - 2-wire, with ground, 120 volt,

single phase, 60 Hz, Alternating Current.

POWER SUPPLY CORD - The dryer is equipped

with a 120 volt 3-wire power cord.

GROUNDING CONNECTION - See “Grounding

requirements” in Electrical Installation section.

Grounding type

wall receptacle

Power cord with

3-prong grounded plug

Do not, under

any circumstances,

cut, remove,

or bypass the

grounding prong.

3-wire receptacle

(NEMA type 10-30R)

4-wire receptacle

(NEMA type 14-30R)

NOTE

Because of potentially inconsistent voltage capabilities, the use of this dryer with power created
by gas powered generators, solar powered generators, wind powered generators or any other
generator other than the local utility company is not recommended.

with clothes dryers. For 3-wire cord connection
instructions see ELECTRICAL CONNECTIONS
FOR A 3-WIRE SYSTEM.

This manual is related to the following products: