Config Menu
The BrightEye 57 can lock to an external house reference or it can lock to its own internal precision
standard reference. From the Config Menu, you can select the overall genlock timing reference,
enable or disable Composite Setup, and select levels for Digital and Analog Audio Reference Levels.
Use the controls to set the following:
• Ref Mode – Affects which source the BrightEye 57 uses for the overall genlock timing
reference. Select Internal to lock to the internal precision standard or Genlock to lock to the
input reference signal. If Genlock is selected but no reference signal is connected, BrightEye
57 will free run. When Internal is selected, the internal precision standard runs at a 10 MHz
accuracy.
• Reference – Reports if a reference signal is connected to the Ref In BNC.
• Sync Lock – Reports the standard the module is locked to. If the module is not locked to a
standard, it displays No Lock.
• Cpst Setup – Select the Enabled checkbox to enable Composite Setup. Composite Setup is
typically enabled.
• Dig Ref Level – Select the digital audio reference level. Choices are -20 dBFS and -18 dBFS.
• Anlg Ref Level – Select the analog audio reference level. Choices are -10 dB, -6 dB, -4 dB,
0 dB, +4 dB.
• Ref VITC Line – Use this control to select the line on which VITC is present. Available choices
are Line 12, Line 13, Line 14, Line 15, Line 16, Line 17, Line 18, Line 19, Line 20, Line 21.