Pattern menu – Ensemble Designs BrightEye 57 3G/HD/SD/Analog Test Signal and Sync Pulse Generator User Manual
Page 24

www.ensembledesigns.com
BrightEye 57
TM
BrightEye 57
3G/HD/SD/Analog Test Signal and Sync Pulse Generator User Guide
Page 24
Pattern Menu
To select the video test pattern, select the Pattern menu shown below. Use the drop-down menus to
set the parameters for the Pattern Sel, Preset 1, Preset 2, and Preset 3 fields. Or select a test pattern
stored on a Secure Digital Memory Card. Enable or disable the Y, Cr and Cb Channels. Determine the
Slate ID parameters.
• Pattern Sel – select the video test pattern for output from the drop-down menu. Choices are:
Black, Flat Field 20, Flat Field 80, 75% Full Bars, 100% Full Bars, 75% Split Bars, 100% Split Bars,
SMPTE Bars, SMPTE 219 Bars, Safe Title, Crosshatch, Preset 1, Preset 2, Preset 3, User Card.
• Preset 1, Preset 2, Preset 3 – select the video test pattern for the Preset fields. To use one
of the Preset test patterns, select from each Preset drop-down menu: Flat Field 50, White,
Red Field Bars, Video Ramp, Data Ramp, Shallow Ramp, 5 Step, Sweep, MultiBurst, Full Field
Window, Component Window, Digital Blanking, Cosite, Interlace, Pathological.
• User Ptn Sel – use the up and down arrows on this control to select a custom video test
pattern stored on the Secure Digital Memory Card. Each number corresponds to one of the
video test patterns on the card.
P
software application. See also the
patterns for use with the BrightEye 57.