beautypg.com

Conversion kit instructions, Dvim33c – Archgard 31-DVIM33C User Manual

Page 15

background image

31-DVIM33C

15


Push orifice strip tab all the way against the hex fitting.

(See Fig B1 & B2)










NG gas position NO 1/16”

hole & NO color visible


LP gas position 1/16” hole

& RED color code visible




On the SIT valve, use a #20 Torx or a slotted screw-
driver to remove and discard the three pressure-
regulator mounting screws (Fig A) the pressure regula-
tor tower (Fig B) and the spring diaphragm assembly
(Fig C)

Ensure that the rubber gasket (Fig D) is
properly positioned and install the new
modulating pressure regulator assembly to
the valve using the screws provided in the
conversion package.




























Install the LP identification label to the
valve (found in kit).

Affix Archgard Manufacturer’s label (part #
303-0128) in a conspicuous location. We
suggest a location close to the gas control
valve.

Check for gas leaks.

Reverse steps to install burner, air tray and
logs

Check inlet & outlet pressures.

Check operation of flame control.

Check for proper flame appearance and
glow on logs.

Fig D

Fig A, B & C

CONVERSION KIT INSTRUCTIONS

Re-tighten the pilot
hood so that it aligns
with the thermopile.
(See Fig C)

View from top of pilot head

I M P O R T A N T

For high altitude installations above 4500 ft (1372 meters), consult local gas distributor or
the authority having jurisdiction for proper de-rating methods.

Fig 24-A

Fig 24-A