Conversion kit instructions, Dvim33c – Archgard 31-DVIM33C User Manual
Page 14

31-DVIM33C
14
CONVERSION KIT INSTRUCTIONS
The installation is not proper and complete until operation of the converted appliance is checked as specified in the instructions sup-
plied with the kit. Refer to appliance owner’s manual or product data plate for proper inlet and manifold pressure adjustments and ori-
fice sizing.
PREPARE THE FIREPLACE
Remove the surround, glass door assembly, logs/media and brick/panels (if applicable).
Remove the burner side brackets and the front ember ledge. The ledge lifts up and out.
Remove burner . Three screws along the top edge of the burner secure it to in place.
KIT NUMBERS:
31-CKMLP for LP gas and 31-CKMNG for Natural Gas
KIT INCLUDES:
1- Gas conversion label (303-0128)
1- Burner orifice (301-0068) (#51 DMS for LPG) (#33 DMS for NG)
1- Gas type Label
1- SIT 820 Valve conversion regulator c/w instructions (0.907.202 ) LPG
(0.907.201 ) NG
PILOT CONVERSION
Using a 7/16” wrench and loosen the pilot hood 1/4
turn. Slide the tab at the bottom of the orifice hood all
the way so the red side (propane) with the hole in it is
showing. Tighten the pilot hood back up so that it is
lined up with the two probes on both sides of the pilot
assembly.
F O R Y O U R S A F E T Y
SHUT OFF GAS SUPPLY AND ELECTRICAL POWER TO FIREPLACE BEFORE BEGINNING THE GAS
CONVERSION
Remove the burner orifice using a 1/2” wrench. Replace with the
orifice supplied with the conversion kit. Use a small amount of
pipe sealant on the threads of the orifice holder.
Fig. 14-A
LP has hole
and red dot
Natural Gas
Fig. 14-B
Wrench here
Fig. 14-C
W A R N I N G
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturers instructions and all applicable
codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explo-
sion or productions of carbon monoxide may result, causing property damage, personal injury or loss of life. The qualified service
agency is responsible for proper installation of this kit.
I M P O R T A N T
This fireplace is Natural gas ready. If converting to LP gas, follow instructions below