beautypg.com

Dvt30n – Archgard 72-DVT30N User Manual

Page 42

background image

72-DVT30N

42


Before servicing, read the terms and conditions of the Archgard warranty at the back of the
manual. Contact the Authorized Archgard dealer were you purchased the appliance from and
provide them with details of the problem together with the initial installation information (from
the back of this manual).

WARNING: Servicing of this appliance must be conducted by a qualified service
technician
. Improper servicing, adjustment or alteration of this appliance may

cause property damage, personal injury or loss of life. All servicing should be
conducted with the appliance cold. All replacement parts must be authorized by
Archgard for suitability.

Caution: Wear gloves when adjusting the primary air with the appliance hot.
Note: the Shutter is set at the factory and normally only requires resetting at higher altitudes.

1.

Open the lower louver.

2.

Unscrew the 2 screws holding the control panel and remove the panel. (Fig. 1)

3.

The primary air adjustment wing nut is located behind and to the left of the control valve.

4.

Loosen the wing nut and slide the primary air shutter to the right to increase primary air
and to left to reduce primary air.

5.

Tighten the wing nut after adjustment.

ADJUSTING PRIMARY AIR

SERVICING UNDER WARRANTY

Fig. 1.

Two Screws

Control Panel

INCREASE

DECREASE

ADJUSTMENT WING NUT

ORIFICE CAP

PRIMARY AIR SHUTTER

Air Shutter (side view)