VENTING - HORIZONTALLY USING SIMPSON DURA-VENT DIRECT VENT SYSTEMS

The Optima 72 can be vented horizontally using Simpson Dura-Vent Direct Vent System. To vent using
Simpson Dura-Vent exclusively, you must use the Archgard 999-DV-SDA Adaptor and connect the 999-
DV-SDA adaptor to the top of the Optima 72 as shown in Fig.1.
NOTE: Apply high temperature sealant to the SDA-U adaptor and the flue connection on the Optima 72.
Follow all venting instructions within this manual.
NOTE: Call your local Authorized Archgard Dealer to purchase Simpson Dura-Vent Direct Vent Kits and/
or venting components.

Wall Thickness (inches)

Vent Length Required (inches)

Wall Thickness (mm)

Vent Length Required (mm)

4” - 5-1/2”

6”

101 mm - 140 mm

152 mm

7” - 8-1/2”

9”

178 mm - 216 mm

228 mm

10” - 11-1/2”

12”

254 mm - 292 mm

305 mm

9” - 14-1/2”

11” - 14-5/8” Adj. Pipe

228 mm - 368 mm

228 mm - 371 mm

15” - 23-1/2

17” - 24” Adj. Pipe

381 mm - 597 mm

432 mm - 610 mm

Flat Wall Installation

Wall Thickness (inches)

Vent Length Required (inches)

Wall Thickness (mm)

Vent Length Required (mm)

3-1/4” - 6-3/4”

11” - 14-5/8” Adj. Pipe

82 mm - 171 mm

228 mm - 371 mm

7-3/4” - 16-1/4”

17” - 24” Adj. Pipe.

197 mm - 412 mm

432 mm - 610 mm

7-1/4” - 8-3/4”

6” + 12”

Or 9” + 9”

184 mm - 222 mm

101 mm + 305 mm

Or 228 mm + 228 mm

4-1/4” - 5-3/4”

6” + 9”

108 mm - 146 mm

152 mm - 228 mm

Corner Installations

Measure wall thickness from the back of the fireplace standoffs to the inside mounting surface of the ter-
mination cap. If a Vinyl siding standoff is required, measure to the outside surface of the wall without
siding and add 2” (50mm).
NOTE: The Termination cap must NOT be recessed into siding. Measure wall thickness including finish-
ing straps.

Minimum components required for horizontal termination using Simpson Dura-Vent:
1 999-DV-SDA (Appliance adaptor)

1 90 Deg. Elbow

1 Horizontal Termination Cap

1 Wall Thimble

1 Length of pipe for top of appliance

1 Length of pipe to suit wall thickness

Part #

Description

971

Horiz. Term. Kit Includes; 90

0

. Blk elbow, wall thimble

cover, Horiz. square term. Cap, 24” (610 mm) blk pipe
and 11”-14” (279 mm x 356 mm) adj. blk pipe.

970

Basic Horiz. Term. Kit Includes; 90

0

. blk elbow, wall

thimble cover, Horiz. square term. cap.

987

Vertical Termination Kit Includes;
0/12- 6/12 pitch adj. flashing, storm collar, low profile
term. cap.

908B 6” (152 mm) Pipe Length - Black

907B 9” (228 mm) Pipe Length - Black

906 12” (305 mm) Pipe Length - Galv.

906B 12” (305 mm) Pipe Length - Black

904

24” (610 mm) Pipe Length - Galv.

904B 24” (610 mm) Pipe Length - Black

903

36” (914 mm) Pipe Length - Galv.

903B 36” (914 mm) Pipe Length - Black

Part #

Description

902

48” (1.22 M) Pipe Length - Galv.

902B

48” (1.22 M) Pipe Length - Black

911B

11” - 14-5/8” (228 mm x 371 mm) Adj. Pipe
Length - Black

917B

17”’ - 24” (432 mm) x (610mm) Adj. Pipe
Length - Black

945

45

0

Elbow - Galv.

945B

45

0

Elbow - Black

945G

45

0

Elbow - Swivel - Galv.

945BG

45

0

Elbow - Swivel - Black

990

90

0

Elbow - Galv.

990B

90

0

Elbow - Black

990G

90

0

Elbow - Swivel - Galv.

990BG

90

0

Elbow - Swivel - Black

991

Vertical Termination Cap High Wind

980

Vertical Termination Cap

Part #

Description

984

Horizontal (Square) Termination Cap

985

Horiz. (SQ) Term. Cap. High Wind.

982

Snorkel - 14” (356 mm) Rise Term. Cap

981

Snorkel - 36” (914 mm) Rise Term. Cap

940

Wall Thimble - Support Box

941

Cathedral/Ceiling - Support Box

3951 Brass Trim for Wall Thimble/Ceiling Sup.

963

Firestop Spacer

943

Flashing 0/12 - 6/12

943S Flashing 7/12 - 12/12

953

Storm Collar

950

Vinyl Siding Standoff

988

Wall Strap

942

Wall Thimble

SIMPSON DURA-VENT DIRECT VENT PARTS LIST 6 ⅝” x 4” (168mm x 101mm)

See your Authorized Archgard Dealer for price and availability.