Open Resevoir Water Temperature Control Units

Page 43

Heaters

Heaters may need to be cleaned chemically or mechanically to
remove deposits and dirt that reduce heat transfer and cause hot
spots. Hot spots cause premature heater failure. Install a new
gasket when reassembling. Make sure a qualified electrician
disconnects and reconnects heater wires.

Solenoid Valves

þ

Clean annually, more often if using high mineral content water

or on high service level units.

þ

Sluggish operation, excessive leakage, and/or noise indicate

cleaning is necessary. Inspect the components for excessive
wear while the valve is disassembled.

þ

Rebuild kits are available from the ACS Group Parts

Department.

6-3 Restoring the Controller to Factory Setup

If the preset parameters on the controller have been tampered with
and it no longer properly controls temperature, you can restore the
controller to factory setup parameters.

6-4 Electrical Connections

Make sure that a qualified electrician inspects all electrical
components and connections every six (6) months for secure
attachment and ground connections. Inspect all wiring for fraying
or damage, especially power lines where they enter the unit. All
wiring connections must be tight
.