Chapter 6: Troubleshooting
28
Problem
Possible cause
Corrective action
Check motor speed. Unit is 
probably running too slow. 
Change gear reducer to a higher 
ratio unit. 
Sometimes operators will let 
the drive hang off the auger 
without removing it fully from 
the housing. This will bend the 
auger.
Check auger to housing 
clearance, and if pellets are 
binding auger, consult factory. 
Check auger for straightness. 
Bent augers are not covered 
under warranty. 
The feeder and 110V loading 
systems may be wired into the 
same outlet. 
Check input voltage and wiring 
size to see if a low voltage 
situation exists. The voltage 
will check out at 120V when 
there is no load. Check the 
voltage when all the units are 
operating at the same time. It 
will sometimes drop 20% or 
more. This indicates that the 
wire size to the outlet is too 
small to carry the load required. 
This condition will normally 
show up first on the loading 
system motors. 
If the drive motor burns out or 
blows fuses. 
?
Check the extruder screw speed 
pick-up proximity switch to 
ensure that it is reading the 
extruder screw revolutions 
accurately. 
Note: Direct any questions you may have concerning our equipment