Loss-In-Weight Color Feeders
Chapter 6: Troubleshooting
27
Problem
Possible cause
Corrective action
?
Check the A/D load cell in 
Diagnostics to ensure that the 
load cell is not damaged and is 
linear. Linearity can be 
checked by adding several 
weights of the same weight to 
the weigh hopper and checking 
to see that the A/D number 
changes the same for each 
weight (The manufacturer 
recommends using large 
washers of the same size). If 
the A/D number is varying 
quite a bit, it will indicate that 
the load cell has been sprung 
or overloaded. It will have to 
be replaced. 
Caution! Use care when
cleaning the unit, 
or it can become 
damaged. 
Caution! Do not pull on the
weigh hopper!
?
Check to see that the additive 
pellets are feeding consistently 
out of the weigh hopper and 
not bridging occasionally in 
the hopper discharge throat. 
Consult the factory if this is 
the case. We also offer a 
larger opening hopper (up to 
2½ inches). The feeder is 
designed for virgin pellet color 
concentrate. It is not 
designed for regrind 
materials. 
If the unit is inaccurate. Cont’d.
?
Check the extruder screw 
speed pick-up proximity 
switch to ensure that it is 
reading the extruder screw 
revolutions accurately. 
 
 
 
 
 
 
 
 
 
 