Disable security encryption
#E1
Enable security encryption on transmitted messages
#E2
Enable security encryption on transmitted messages and enforce encryption on
received msgs.
AT#N
Enter Module Serial Number (11 characters Max) (Requires Radio Access AT#R
to change).
AT#O
Control digital I/O point
#O0
Turn digital I/O point off (And enable as an input)
#O1
Turn digital I/O point on
#O2
Digital I/O point reflects communications link
#O5
Dual Redundancy – Change from Primary to Secondary
#O6
Dual Redundancy – Change from Secondary to Primary
AT#P
Set the Remote Access Password. This password must be entered by a remote
user before accessing the module over the radio (Also #A1 must be set).
AT#R
Enter Radio Access Password – Enables radio commands until next reset.
AT#S
Enter AES Security key.
AT#V
Enter Hardware Revision (7 characters Max) (Requires Radio Access AT#R to
change).
AT&Axx
RS-485 Serial port Character Type (Data bits, Stop bits, Parity)
0
8 data, No parity, 1 Stop Bit
1
8 data, No parity, 2 Stop Bits
2
7 Data Bits, Even Parity, 1 Stop bit
3
7 Data Bits, Odd Parity, 1 Stop bit
4
8 Data Bits, Even Parity, 1 Stop bit
5
8 Data Bits, Odd Parity, 1 Stop bit
AT&Bxx
RS-232 Serial port Character Type
0
8 data, No parity, 1 Stop Bit
1
8 data, No parity, 2 Stop Bits
2
7 Data Bits, Even Parity, 1 Stop bit
3
7 Data Bits, Odd Parity, 1 Stop bit
4
8 Data Bits, Even Parity, 1 Stop bit
5
8 Data Bits, Odd Parity, 1 Stop bit
AT&C
Data Carrier Detect (DCD) Control.
&C0
DCD Always on.