background image

© 2014 Wavetronix LLC. All rights reserved. Protected by US Pat. Nos. 6,556,916; 6,693,557; 7,426,450; 7,427,930; 7,573,400; 7,889,097; 7,889,098; 7,924,170; 7,991,542; 8,248,272;

8,665,113; and Cdn. Pat. Nos. 2,461,411; 2,434,756; 2,512,689; and Euro. Pat. Nos. 1435036; 1438702; 1611458. Other US and international patents pending. Wavetronix, SmartSensor, Click,

Command and all associated logos are trademarks of Wavetronix LLC. All other product or brand names as they appear are trademarks or registered trademarks of their respective hold-

ers. Product specifications are subject to change without notice. This material is provided for informational purposes only; Wavetronix assumes no liability related to its use.

3

Ground the device

4

Wire communication

The Click 330/331 have two possible communication ports.

˽

RJ-45 jacks (Click 330 and 331) – Attach Ethernet cables here

˽

SC fiber optic connectors (Click 331) – Attach fiber optic cables by pushing the connector down until it

engages with a click

The device has a grounding foot, so as long as

the DIN rail is properly grounded, the device

will be grounded as well.
However, for additional protection, the switch

can be grounded via an eyelet ring on the top

of the device.

WX-500-0188

5

Monitor LEDs

The devices have three different kinds of LEDs.

˽

At the top of each device are two green LEDs

labeled US1 and US2, used for monitoring the

power supply. US1 monitors the first power supply

(the one using the screw terminal marked US1)

and US2 monitors the second (redundant) power

supply.

˽

Each Ethernet port has two LEDs that show the data transmission speed of that port, as shown in the

table below. These LEDs are labeled 100/ACT and 1000/ACT. If the LED is on, there is an electrical link.

If the LED blinks, there is currently network traffic at that speed.

LED

10 Mbps

100 Mbps

1000 Mbps

100/ACT

On or blinking

On or blinking

Off

1000/ACT

On or blinking

Off

On or blinking

˽

The fiber ports on the Click 331 each have an LED labeled 1000 LNK/ACT. If this LED is on, there is a

valid connection through that port. If the LED blinks, there is currently network traffic at 1000 Mbps.

Status

Meaning

On

Supply voltage is in an acceptable range

Off

Supply voltage is too low