5

Connect via laptop or handheld computer

The Click 421 cannot initiate a connection; that must be done by a

laptop or handheld computer with Bluetooth capabilities:
1 Open the Bluetooth Manager program on the laptop or hand-

held.

2 Discover available Bluetooth devices.

3 Select the Click 421 from the list. It will appear under the name

“CK421-xxxxxxx” where the string of x’s represents the device

serial number. If you’d like to change the name of your Bluetooth

device, that will be covered in the next four parts of this docu-

ment.

Note. Depending on your computer, you may be asked for a password

during the connection process, even if you haven’t set one up; if so, use the password “default.”

6

Install Click Supervisor

Note. Your Click 421 is now fully functional. If you don’t wish to make any other

changes to configuration, you don’t need to follow parts 6–9. However, the Click

421 can be further configured using Click Supervisor software. Click Supervisor

will enable you to change the Bluetooth device name and other settings.

Follow these steps if you want to install Click Supervisor:
1 Download the setup file from www.1 wavetronix.com (under Support).

2 Open the file to run the setup wizard. Follow the steps to install.

7

Make a connection

To make a connection to your Click 421:
1 Make sure there is a connection between the Click 421 and the computer that Click Supervisor is on.

This link is available through the Bluetooth connection, but if for some reason the Bluetooth link is not

available—for instance, the computer that Click Supervisor is on does not have Bluetooth capabilities—

this can be made through the DB-9 connector on the front of the module or through a DB-9 connector

on another device that is also on the T-bus.

2 Run Click Supervisor and select Communication. This screen lets you pick the

type of connection you want to make, serial or IP. In most cases, the Click 421

will be configured using serial communication.

3 Click Settings to make any necessary changes to the settings, such as the port or

the baud rate. Click OK to return to the Communication screen, then click Con-

nect. Keep the Click ID set to 0.

4 In the next screen, Click Supervisor will display all the devices it discovers.

When the Click 421 appears, select it and click Select. Click Supervisor will con-

nect to the device.