Form: WMS-OE331-21-GPCPlusController-01A.doc

Page

1 of 1

VAV System

Description

The OE331-21 General Purpose Con-
troller Plus (GPC Plus) is used for con-
trolling equipment or processes that can-
not be controlled using HVAC controllers.
The Prism computer front end software is
used to interface with the GPC Plus con-
troller functions. The GPC Plus Controller
provides the flexibility to control, schedule
and/or monitor equipment such as unit
heaters, exhaust fans, motorized louvers,
etc.. The GPC Plus has (6) configurable
inputs which will accept signals from
thermistor temperature sensors, 4-20mA
or 0-5VDC transmitters or dry contact
closures. An additional modular input is
provided for connection of an OE271
static pressure sensor. The GPC Plus
has (5) relay outputs for on/off control
and (2) analog outputs. With the addition
of the OE352 2 Slot Expansion Base
Board and (1) OE357 4 Relay Expansion
Board, (4) additional relay outputs are
available providing for a maximum of (9)
usable relay outputs. The GPC Plus also
has (5) separate 2 event per day sched-
ules, each with its own optimal start func-
tions built in. In addition the GPC Plus
provides lead/lag start capabilities.

Mounting

The GPC Plus is provided with an integral backplate for mounting inside of a control enclosure. It is recom-
mended that the GPC Plus be mounted in the HVAC unit control enclosure, or in a control enclosure in the
building equipment room. An optional factory control enclosure for the GPC Plus is available.

OE331-21-GPC Plus

GPC Plus Controller

Technical Data

OE331-21-GPCPLUS

GPC Plus Controller

Power

24 Volt AC

Weight

1.5 lb.

Power Consumption

8 VA Maximum

Network Connection

RS-485

Operating Temp

10

°F to 149°F Protocol

HSI Open Protocol Token Passing

Operating Humidity

90% RH Non-Condensing

Communications

RS-485 - 9600 Baud

Inputs:

Outputs:

Type III-10kohm sensors

Total Relay Qty. On Board

5

4-20ma sensors

N.O. Binary Contact

Total Relay Qty. Available With
Optional Expansion Board

9

Types of Allowed
Inputs

N.C. Binary Contact

Relay Power Rating

(2 Amp @ 24 VAC)

Total Inputs Available

7

Analog Output Qty.

2

Static Pressure Inputs

1 (Modular )

Analog Output Signal

0-10 VDC

Configurable Inputs

6

Optimal Start Schedules

(5) Total - (1) for Each Schedule

Schedules Available

(5) 2 Event per day

Lead Lag Scheduling

(1) Output can be Configured

Three Year Warranty

WattMaster reserves the right to change specifications without notice

RL

Y

1

D1

D2

D3

D4

D5

CX

3

RAM

EPROM

C3

C2

U6

PH

IL

IP

S

CX6

C1

CX2

U2

U3

PAL

CX4

U4

TUC-5R PLUS

YS101816 REV. 2

V1

V2

V3

V5

V4

TB2

4

NETWORK

TOKEN

16

32

8

SW1

ADD

2

1

ADDRESS

V6

PO

W

ER

GND

24VAC

L1

D1

6

R6

C9

SC1

R1

1

U1

1

MC

34064

A

D1

3

C16

9936

VR2

7824C

T

M

TB4

R27

C13

R1

0

VR1

C1

9

C1

8

NE5090NPB3192

0PS

U8

CX

8

U9

X1

R7

D1

0

R13

D12

C7

CX10

U10

CX12

U12

U14

CX14

PJ3

PJ2

PJ1

EXPANSION

PRESSURE
SENSOR

T'STAT

C17

D15

R26

C20

R25

R24

R22

U15

CX13

U13

C15

R19

R15

C14

D1

8

D1

7

PU1

PU2

PU3

PU4

PU5

PU7

D6

D7

D8

D9

D11

D14

C12

C10

0-

5

VD

C

0-

1

VD

C

JP1

C1

1

X2

GND

TB3

INPUTS

GND

GND

+VDC

AIN1

AIN2

AIN3

AIN4

AIN5

AOUT1

AOUT2

AIN7

RN

4

1

RN5

RS-485

CX5

U5

R

TB1

SHLD

T

COMM

COMM

RN

3

1

RN1

U1

CX1

1

LD6

COMM

PWR

LD7

LED1

LED2

LD9

LD8

R1

U7

RV1
VREF ADJ

R28

+VREF

5.11V

TEST POINT

EWDOG

D19

RN2

1

COM1-3

COM4-5

R5

R4

R3

R2

R1

RL

Y

2

RL

Y

3

RL

Y

4

RL

Y

5

CX15

(1 MEG)

HH

P1

C2
1

6.2“

6.6”

7.3”

6.7”

1.1”

.20 Dia.
Typ. of 4

This manual is related to the following products: