Operator’s manual df32 – Watson-Marlow DF32 User Manual
Page 21

Operator’s manual
DF32
Rev.: 1.03 Date: 2007-03-12 Page 21 of 32
File:
DF32 OM 1.03 EN
F10: gives a current indication of the number of fills completed per minute.
The fills have not been calibrated. For this function, please see chapter 5 of this manual.
7.5 Stop
filling
When DF32 has completed the number of fills asked for in DF32: it will stop automatically.
If
If you want to stop the filling before the programmed number has been completed, press
and DF32 will stop after completing the filling in progress.
The filling series can be completed by pressing
If you want to stop IMMEDIATELY, such as in the middle of a fill, press
stop immediately.
The filling series can be completed by pressing
included.
7.6 Used as a pump
DF32 can also be used as a pump.
In this case only tube diameter and velocity should be entered.
Start the pumping by pressing
DF32 will start with the entered acceleration and run up to the required number of revolutions per
minute.
DF32 will pump at this velocity until stopped by pressing
7.7 Used with a bottle handling system
DF32 can also be used together with a bottle handling system like FlexFeed 20 from Flexicon.
When DF32 is integrated in an automatic bottle handling system, it is important to observe the
following:
The batch size in case of running with a bottle handling system must be set to 1.
The DF32 should be in dispense mode before starting the fill sequence.
The Go signal which activates filling should be generated by the bottle handling system.
The Go signal should be inserted into DF32 via External Go port.
For information on External Go port, please refer to section 10.