beautypg.com

Operator’s manual df32 – Watson-Marlow DF32 User Manual

Page 20

background image

Operator’s manual
DF32

Rev.: 1.03 Date: 2007-03-12 Page 20 of 32

File:
DF32 OM 1.03 EN














Fig. 7.4

7.4 Used as a filler

Switch on DF32 and press .

Example of filling job:
Volume: 50

ml

Velocity: 250

rpm

Acceleration: 35
Small back suction.

100 fills to be completed

A delay of 1.1 seconds between the fills.

Product with specific gravity of 1.0

The above job is to be programmed as follows:


The above job is programmed:

Volume: <1>++<5>+<0>+
Velocity: <3>++<2>+<5>+<0>+
Acceleration: <4>++<3>+<5>+
Back suction:

<5>++<1>+

Number of fills:

<6>++<1>+<0>+<0>+

Delay: <7>++<1>+<.>+<1>+
Specific Gravity

<9>++<1>+<.>+<0>+


You have now programmed the DF32 for the job, but want to reset the built- in counters. In function 8
the counters indicate "number of completed fills".

Number of fills:

<8>+++


Now inform DF32 that you want to enter filling mode by pressing .
Every time or the foot switch is pressed, or every time an electric signal is given, DF32 will run
100 fills of 8.5 ml with a delay of 1.1 seconds between the fills.

Press , verify that DF32 starts and let it run.
Press ARROW DOWN until you see function 8 on the status line and that F8: is counting each fill.

Hopper

The support is fixed by
use of 2 screws.
M4 x 35.

The support must be
resting on the surface
that DF32 stands on.