Operator’s manual df32 – Watson-Marlow DF32 User Manual
Page 20

Operator’s manual
DF32
Rev.: 1.03 Date: 2007-03-12 Page 20 of 32
File:
DF32 OM 1.03 EN
Fig. 7.4
7.4 Used as a filler
Switch on DF32 and press
Example of filling job:
Volume: 50
ml
Velocity: 250
rpm
Acceleration: 35
Small back suction.
100 fills to be completed
A delay of 1.1 seconds between the fills.
Product with specific gravity of 1.0
The above job is to be programmed as follows:
The above job is programmed:
Volume: <1>+
Velocity: <3>+
Acceleration: <4>+
Back suction:
<5>+
Number of fills:
<6>+
Delay: <7>+
Specific Gravity
<9>+
You have now programmed the DF32 for the job, but want to reset the built- in counters. In function 8
the counters indicate "number of completed fills".
Number of fills:
<8>+
Now inform DF32 that you want to enter filling mode by pressing
Every time
100 fills of 8.5 ml with a delay of 1.1 seconds between the fills.
Press
Press ARROW DOWN until you see function 8 on the status line and that F8: is counting each fill.
Hopper
The support is fixed by
use of 2 screws.
M4 x 35.
The support must be
resting on the surface
that DF32 stands on.