6.5 List of functions
1. Volume
21. Batch number
3. Velocity
24. Print status
4. Acceleration/deceleration
29. Print parameters
5. Reversing (back suction)
31. Save program
6. Batch size
32. Load program
7. Delay
33. Delete program
8. Completed fills
34. Print programs
9. Specific gravity
46. Set language
10. Filling rate
47. Printer set-up
15. Input mode
72. Volume format
18. Timer 2
80. Reset memory
20. Operator number
6.6 Description
of
functions
The individual functions will be described in the following:
1. Volume
Value: Choice of ml and grams.
Required volume from 0.01 to 9999.9 ml.
3. Velocity
Value: Revolutions per minute (rpm).
Enter the required velocity.
Min.: 30 rpm.
Max.: 500 rpm.
4. Acceleration/deceleration
Value: An integral number.
The filling can start and stop more or less abruptly.
This function offers a choice of values between 1 and 100.
1
= slowest acceleration.
100 =
fastest
acceleration.
5. Reversing (back suction)
Value: An integral number.
When the filling stops, the filler can be asked to produce a minor back suction to prevent dripping.
The back suction can be set at values between 0 and 10.
0 = no back suction.
10 = maximum back suction.