INSTALLATION AND MAINTENANCE

VARMECA 30

Variable speed motor or geared motor

CONNECTIONS

LEROY-SOMER

3776 en - 07.2007 / h

en

3.6 - Power supply and control for
FCR brake motors

3.6.1 - Power supply for the built-in fixed
control brake (SO VMA option) VMA 31/32 only

- The brake is supplied via the rectifier fixed on the SO VMA
connection card. This connection is made at the factory.
- The rectifier is supplied by a mains phase and the motor star
point.
- No parameters need to be set on the VARMECA.
- The brake is released as soon as the VARMECA run
command is enabled. The brake is released after a stop
command, at the end of the deceleration ramp or on
disconnection of the power supply.

3.6.2 - Power supply for the built-in
sequential control brake (VMA ESFR option)

- The brake is supplied via the rectifier and a solid state relay
fixed on the VMA ESFR connection card. This connection is
made at the factory.
- The rectifier is supplied by two mains phases.
- The brake is controlled according to a sequence which can
be adjusted using the VARMECA parameters.

3.6.3 - Separate power supply

The brake is supplied and controlled by an external source.